This OEM hot surface igniter kit fits the ICP / Tempstar / Heil RGS101LRBA0AAAA gas furnace and includes the ignitor (P/N 1171306) and its dedicated wiring kit (P/N 1188370). On a call for heat, the control board energizes the igniter, which glows red-hot and lights the burner gas. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that crack with age, thermal cycling, or a fingerprint on the element — a cracked igniter is the single most common cause of furnace no-heat lockouts.
| Spec | Value |
|---|---|
| Part Numbers | 1171306 (Igniter), 1188370 (Wiring Kit) |
| Type | Hot Surface Igniter |
| Brand | ICP / Tempstar / Heil |
| Application | Furnace burner ignition |
| Fitment | OEM direct replacement |
Engineered for the ICP-built RGS101LRBA0AAAA gas furnace and related Tempstar, Heil, Comfortmaker, and ICP models using the same hot surface ignition system and connector.