Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS101LDBA0AAAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS101LDBA0AAAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit (igniter part 1171306 plus wiring kit 1188370) is the factory ignition component for the ICP / Tempstar / Heil RGS101LDBA0AAAA gas furnace. The hot surface igniter (HSI) is a silicon nitride or silicon carbide element that glows red-hot when energized, igniting the gas at the burners during each heating cycle. Because it is electrically and thermally cycled on every call for heat, it is one of the most common wear items in a modern furnace. A cracked or aged element causes ignition failure, short cycling, and ultimately a no-heat lockout. The included wiring kit ensures a clean, correct connection to the furnace control board so the new element seats and fires reliably.

Specifications

Spec Value
OEM Igniter Part Number 1171306
OEM Wiring Kit Part Number 1188370
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fits Model RGS101LDBA0AAAA

Compatibility

Designed as the direct OEM replacement for the ICP / Tempstar / Heil RGS101LDBA0AAAA furnace. Confirm your furnace uses a hot surface ignition system and match the igniter mounting and connector before installing. The wiring kit adapts the new element to the original furnace harness.

Installation Guide

  1. Safety First — Shut off gas and disconnect power to the furnace; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old element by the ceramic base only.
  5. Install — Mount the new igniter without touching the element, then connect the supplied wiring kit to the harness.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the trial-for-ignition period.

Signs You Need a Replacement

  • Furnace clicks and tries to light but produces no flame
  • Igniter no longer glows or glows weakly/unevenly
  • Visible crack, chip, or white spot on the element
  • Furnace short cycles or goes into ignition lockout

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LDBA0AAAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LDBA0AAAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LDBA0AAAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online