Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS101HTBA0AAAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS101HTBA0AAAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part 1171306) for the ICP / Tempstar / Heil RGS101HTBA0AAAA gas furnace, available with the matching igniter wiring kit (part 1188370). The hot surface igniter is the heating element that glows red-hot at the start of every heat cycle to ignite the gas as it leaves the burners. Because the element is brittle silicon carbide or silicon nitride that is heated and cooled hundreds of times per season, it is the single most common no-heat failure on modern furnaces. The included wiring kit refreshes the igniter connector and leads, which often degrade alongside the element.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Element Silicon carbide
Application Gas furnace ignition
Includes Igniter wiring kit

Compatibility

Designed for the ICP-built RGS101HTBA0AAAA furnace and the equivalent Tempstar, Heil, Comfortmaker, and Day & Night models. Confirm your model number before ordering.

Installation Guide

  1. Safety First — Turn off the gas and disconnect electrical power. Verify zero voltage at the control board with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the igniter bracket position and wiring routing before removal.
  4. Remove — Unplug the igniter connector and remove the mounting screw, then carefully lift out the old igniter without touching the new element with bare fingers.
  5. Install — Mount the new igniter, install the wiring kit, and reconnect the connector so the element sits in the burner flame path.
  6. Test — Restore gas and power and watch a full ignition sequence to confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace blows cold air or locks out on ignition failure
  • Igniter does not glow during the ignition sequence
  • Visible cracks, blistering, or breaks in the element
  • Repeated short-cycling on a call for heat

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HTBA0AAAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HTBA0AAAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HTBA0AAAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online