Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS091SRCA0AAA — OEM 1171306 + Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS091SRCA0AAA — OEM 1171306 + Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit pairs the genuine igniter (part number 1171306) with the matching igniter wiring kit (part number 1188370) for the ICP Tempstar Heil RGS091SRCA0AAA furnace. On each heat call, the control board sends line voltage to the igniter, which glows white-hot to ignite the gas at the burners. The brittle silicon-carbide/silicon-nitride element is a wear item that cracks from thermal cycling, contamination, or rough handling. When it fails, the furnace draws the inducer and opens the gas valve but never lights — resulting in no heat and often a lockout fault. The included wiring kit replaces aged, heat-stiffened leads and connectors so the new igniter gets a clean, reliable connection.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot surface igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Fitment OEM replacement
Includes Igniter + wiring/harness kit

Compatibility

Factory igniter for the ICP/Tempstar/Heil RGS091SRCA0AAA gas furnace and related ICP-family models using the same igniter mount and connector. Because ICP shares ignition components across its Tempstar, Heil, Comfortmaker, and Arcoaire lines, the 1171306 igniter and 1188370 wiring kit fit a range of compatible furnaces. Verify the mounting tab and plug style match your old igniter before installing.

Installation Guide

  1. Safety First — Disconnect furnace power and verify zero voltage with a multimeter. Handle the new igniter by its ceramic base only — never touch the element.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wiring before removal.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter without bumping the element.
  5. Install — Mount the new 1171306 igniter in the exact position, install the 1188370 wiring kit, and reconnect the harness.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs the inducer but never ignites (no glow)
  • Visible crack or break in the igniter element
  • Repeated ignition-lockout fault codes
  • Intermittent or delayed lighting with a rough "poof" on start

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091SRCA0AAA — OEM 1171306 + Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091SRCA0AAA — OEM 1171306 + Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091SRCA0AAA — OEM 1171306 + Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online