Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS091LTCA0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS091LTCA0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP / Heil / Tempstar RGS091LTCA0AAA gas furnace includes the igniter (part 1171306) and its matching wiring harness kit (part 1188370). On each heat call the control board sends line voltage to the igniter, which glows white-hot to ignite the gas at the burners. Hot surface igniters are brittle and degrade with every cycle; a cracked element, contaminated surface, or frayed harness leads to no ignition, delayed ignition, or repeated lockouts. Replacing the igniter together with a fresh wiring kit restores reliable, fast light-off.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Includes Igniter + wiring harness kit
Application Gas furnace ignition
Fitment OEM direct replacement

Compatibility

Designed for the ICP-family RGS091LTCA0AAA gas furnace and related RGS091 series units calling for igniter 1171306 with wiring kit 1188370. Verify your igniter part number and connector style before installing.

Installation Guide

  1. Safety First — Turn off gas and electrical power. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner access panel.
  3. Document — Photograph the igniter mounting position and the harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter. Handle only by the ceramic base — never touch the element.
  5. Install — Mount the new igniter, route and plug in the new wiring kit per your photos, keeping the element clear of the burner.
  6. Test — Restore gas and power, then watch a full heat cycle to confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blows cold air or locks out with no flame
  • Igniter no longer glows orange/white on a heat call
  • Visible cracks, chips, or white spots on the igniter element
  • Delayed ignition or a loud whoomp at light-off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LTCA0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LTCA0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LTCA0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online