Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS091LTBA0AAAA — With Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS091LTBA0AAAA — With Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for ICP/Tempstar/Heil gas furnace model RGS091LTBA0AAAA includes the igniter (OEM part 1171306) and the matching igniter wiring kit (OEM part 1188370) for a complete, ready-to-install replacement. A hot surface igniter (HSI) is the element that glows red-hot when the furnace control board energizes it, igniting the gas at the burners on each heat call. Igniters are a wear item — the element becomes brittle and eventually cracks from repeated heating and cooling cycles. The included wiring kit ensures a clean electrical connection and is the recommended companion to any igniter replacement, since brittle or heat-damaged igniter leads are a frequent cause of repeat no-heat failures. Replacing the HSI restores reliable ignition and eliminates the long, frustrating no-heat lockouts caused by a failed igniter.

Specifications

Spec Value
OEM Igniter Part Number 1171306
OEM Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + Igniter Wiring Kit
Fits Model RGS091LTBA0AAAA

Compatibility

Designed for ICP-family gas furnaces (Tempstar, Heil, Comfortmaker, Arcoaire) and a direct fit for model RGS091LTBA0AAAA. Confirm your furnace uses igniter part 1171306 (or a listed supersession). The included wiring kit 1188370 adapts the new igniter to the existing furnace harness.

Installation Guide

  1. Safety First — Shut off gas and electrical power to the furnace. Verify zero voltage with a multimeter before working near the burner assembly.
  2. Access — Remove the furnace burner / blower access panel to reach the igniter at the burner manifold.
  3. Document — Photograph the igniter mounting position and wiring connection before removal.
  4. Remove — Unplug the igniter lead, remove the mounting screw(s), and carefully withdraw the old igniter — never touch the ceramic element with bare fingers.
  5. Install — Mount the new 1171306 igniter in the exact original position, then connect the 1188370 wiring kit, handling the element only by its ceramic base.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows bright and the burners light promptly and evenly.

Signs You Need a Replacement

  • Furnace blower runs but burners never light (no-heat)
  • Igniter no longer glows or glows weak/uneven
  • Visible cracks or breaks in the ceramic element
  • Repeated ignition lockouts or short cycling on heat calls

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LTBA0AAAA — With Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LTBA0AAAA — With Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LTBA0AAAA — With Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online