Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS091LRBB0AAAA — OEM with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS091LRBB0AAAA — OEM with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This kit includes the OEM hot surface igniter (part number 1171306) and the matching igniter wiring kit (part number 1188370) for the ICP / Heil / Tempstar RGS091LRBB0AAAA gas furnace. The hot surface igniter glows red-hot when the control board energizes it, lighting the burners at the start of each heat cycle. Igniters are brittle and wear out — they crack from thermal cycling, develop hot spots, and eventually fail to reach ignition temperature, leaving the furnace with no heat. The included wiring kit provides a fresh igniter harness so you replace the connector and leads at the same time, preventing the intermittent no-light faults caused by a heat-damaged plug.

Specifications

Spec Value
Part Number (Igniter) 1171306 (IGNITOR)
Part Number (Wiring) 1188370 (WIRING KIT IGNITER)
Type Hot surface igniter
Brand ICP / Heil / Tempstar
Voltage 120 VAC
Application Gas furnace burner ignition

Compatibility

Direct-fit for the ICP/Heil/Tempstar RGS091LRBB0AAAA furnace and other RGS-series units that use igniter 1171306 with the 1188370 harness. Confirm your original igniter part number before ordering, as mounting bracket and connector styles vary across furnace families.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage; the igniter operates on 120V.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting position and wiring connector before removal.
  4. Remove — Unplug the igniter harness, remove the igniter mounting screw, and carefully lift out the fragile old igniter without touching the element.
  5. Install — Mount the new 1171306 igniter (handle by the ceramic base only), then connect the new 1188370 wiring harness.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace clicks and tries to ignite but produces no heat
  • Igniter does not glow during the ignition sequence
  • Visible cracks, breaks, or white hot spots on the igniter element
  • Intermittent ignition or repeated lockout fault codes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LRBB0AAAA — OEM with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LRBB0AAAA — OEM with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LRBB0AAAA — OEM with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online