This OEM igniter kit for the ICP RGS091LRBA0AAAA furnace pairs the hot surface igniter (P/N 1171306) with its dedicated wiring kit (P/N 1188370). The igniter is the component that glows red-hot when the furnace calls for heat, lighting the gas at the burners. Over thousands of heating cycles the igniter element becomes brittle and eventually cracks, producing a no-heat condition where the furnace draws but never lights. The included wiring kit provides the correct harness and connector so the new igniter mates cleanly to the control board — important because aging connectors are a frequent cause of intermittent ignition. Replacing the igniter and its harness together restores dependable, fast ignition.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter with Wiring Harness
Brand ICP / Tempstar / Heil
Function Burner Ignition
Fitment OEM
Model RGS091LRBA0AAAA

Compatibility

Designed for the ICP / Tempstar / Heil RGS091LRBA0AAAA gas furnace and related models using this hot surface igniter and harness. Verify your existing igniter style before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and shut off the gas; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the old igniter harness and unscrew the igniter bracket. Handle the new igniter by the ceramic base only — never touch the silicon nitride/carbide element.
  5. Install — Mount the new igniter in the correct position, then connect the new wiring kit between the igniter and control board.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace draws and clicks but never lights (no flame)
  • Visible crack or break in the igniter element
  • Igniter no longer glows during a heat call
  • Intermittent ignition or repeated lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LRBA0AAAA — Igniter + Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LRBA0AAAA — Igniter + Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LRBA0AAAA — Igniter + Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.