This OEM hot surface igniter (part number 1171306) with its matched igniter wiring kit (part number 1188370) is the ignition component for the ICP / Tempstar / Heil RGS091LECB0AAA gas furnace. On a heat call, the furnace control sends line voltage to the igniter; it glows orange-hot in seconds and lights the burner gas. It is the single most-replaced wear item in a modern furnace because the brittle silicon carbide or nitride element degrades with every heating cycle.

The included wiring kit provides the correct connector and harness so the new igniter seats and plugs in cleanly without splicing. A cracked or worn igniter is the classic cause of "no heat" complaints where the inducer runs, the gas valve clicks, but the burners never light and the furnace locks out.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + wiring/connector kit
Application Gas Furnace Ignition
Fitment OEM Replacement

Compatibility

Fits the ICP / Tempstar / Heil RGS091LECB0AAA furnace and other ICP-family furnaces that call for OEM igniter 1171306. Verify your existing igniter part number and connector style before installing.

Installation Guide

  1. Safety First — Turn off the gas and disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/blower access panel.
  3. Document — Photograph the igniter mounting position and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw, handling the old igniter only by its ceramic base — never touch the element.
  5. Install — Mount the new igniter (touch only the base), route and plug in the wiring kit, and confirm the element clears the burner.
  6. Test — Restore gas and power, start a heat call, and watch for a clean glow and burner light-off.

Signs You Need a Replacement

  • Furnace runs the inducer but burners never ignite (no heat)
  • Visible cracks or breaks in the igniter element
  • Igniter glows weakly or not at all on a heat call
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LECB0AAA — Includes Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LECB0AAA — Includes Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LECB0AAA — Includes Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.