Overview

This OEM hot surface igniter assembly is the ignition source for the ICP/Tempstar/Heil RGS091LEBA0AAAA gas furnace. On a call for heat, the integrated furnace control energizes the igniter (OEM part 1171306); it glows to roughly 1,800–2,500°F and ignites the gas at the burners. This listing pairs the igniter element with the matching igniter wiring kit (OEM part 1188370) so the connector and harness are replaced together — a common failure point when the original element cracks. Hot surface igniters are brittle silicon-based elements that degrade with every heating cycle. A failed igniter is one of the single most common causes of "no heat" in modern furnaces.

Specifications

Spec Value
OEM Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas furnace ignition
Fitment RGS091LEBA0AAAA

Compatibility

Engineered for the ICP family gas furnace model RGS091LEBA0AAAA and shared-platform Tempstar, Heil, Comfortmaker, and Arcoaire units that use the 1171306 igniter. Always confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter. Never touch the new element's surface with bare fingers — skin oils cause early failure.
  5. Install — Mount the new igniter to the bracket, then connect the new wiring kit per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace blower runs but no ignition / no heat
  • Visible cracks or breaks in the igniter element
  • Igniter never glows during a heat call
  • Repeated lockouts after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LEBA0AAAA — Silicon Nitride | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LEBA0AAAA — Silicon Nitride | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LEBA0AAAA — Silicon Nitride | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.