Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS091LDCB0AAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS091LDCB0AAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306), supplied with wiring harness kit 1188370, is the ignition source for ICP, Tempstar, and Heil RGS091-series gas furnaces. On a call for heat the control board sends line voltage to the igniter, which glows white-hot to light the burners. Hot surface igniters are brittle and consumable — the silicon carbide or nitride element degrades with every heat cycle and eventually cracks or fails open. The classic symptom is a furnace that runs the inducer and clicks the gas valve but never lights, often cycling on the limit or going into lockout. The included wiring kit ensures a clean, correct connection to the existing harness.

Specifications

Spec Value
Part Number 1171306 (igniter)
Included Kit 1188370 (igniter wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fitment OEM exact-fit

Compatibility

Designed for the ICP/Tempstar/Heil RGS091LDCB0AAA and other RGS091-series gas furnaces using this igniter and harness. Confirm the igniter mount and connector against your unit before ordering.

Installation Guide

  1. Safety First — Disconnect power; verify zero voltage with a multimeter. Handle the new igniter by its base only — never touch the element.
  2. Access — Remove the burner/service panel.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s); discard the old igniter.
  5. Install — Mount the new igniter so it sits correctly over the burner, then connect using the supplied wiring kit.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs inducer and clicks gas valve but never lights
  • Igniter does not glow on a call for heat
  • Visible cracks, breaks, or white spots on the element
  • Repeated ignition lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LDCB0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LDCB0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LDCB0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online