Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS091HTBA0AAAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS091HTBA0AAAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM hot surface igniter (part 1171306) with the matching igniter wiring kit (part 1188370) for the ICP Tempstar Heil RGS091HTBA0AAAA gas furnace. The hot surface igniter glows to a high temperature when energized by the control board to ignite the gas at the burner. Igniters are brittle and degrade with every heating cycle — they crack, develop hot spots, and eventually fail open. The included wiring kit ensures a clean, secure electrical connection. When the igniter fails, the furnace will not light and you will typically see ignition-failure lockout codes.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter element + wiring harness kit
Fits Model RGS091HTBA0AAAA

Compatibility

Designed for the ICP / Tempstar / Heil RGS091HTBA0AAAA and related RGS-series gas furnaces using this igniter platform. Confirm the part number and mounting orientation against your existing igniter before installing. Handle the new igniter only by its ceramic base — skin oils shorten its life.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector and unscrew the old igniter, taking care not to touch the new element.
  5. Install — Mount the new igniter in the same orientation and connect it using the included wiring kit.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light within the normal ignition sequence.

Signs You Need a Replacement

  • Furnace will not ignite and locks out
  • Igniter shows visible cracks, blistering, or no longer glows
  • Repeated ignition-failure fault codes
  • Open circuit when the igniter is tested for continuity

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns on unused parts in original packaging. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HTBA0AAAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HTBA0AAAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HTBA0AAAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online