Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS091HSBA0AAAA — Igniter + Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS091HSBA0AAAA — Igniter + Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP Tempstar Heil RGS091HSBA0AAAA gas furnace includes the igniter (P/N 1171306) and the matching igniter wiring kit (P/N 1188370). On each call for heat, the control board sends voltage to the igniter, which glows red-hot to light the gas burners. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that crack, develop hairline fractures, or simply wear out from thousands of heating cycles. A failed igniter is one of the most common no-heat causes: the inducer runs, the gas valve may open, but the burners never light and the furnace locks out. The included wiring kit replaces brittle, heat-damaged leads and connectors for a complete, reliable repair.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter element + wiring harness kit
Application Furnace burner ignition
Fitment OEM direct replacement

Compatibility

Built for the ICP / Tempstar / Heil RGS091HSBA0AAAA gas furnace and related ICP-family models using this hot surface ignition system. The wiring kit ensures a correct connector match to the furnace control board.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wiring connector before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and carefully withdraw the fragile igniter — never touch the element with bare fingers.
  5. Install — Mount the new igniter (handle by the ceramic base only), route and connect the new wiring kit, and secure the harness clear of hot surfaces.
  6. Test — Restore power, call for heat, and confirm the igniter glows and the burners light within the ignition window.

Signs You Need a Replacement

  • Furnace inducer runs but burners never light (no-heat lockout)
  • Visible cracks or breaks in the igniter element
  • Igniter glows weakly or not at all
  • Repeated ignition-failure error flashes on the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HSBA0AAAA — Igniter + Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HSBA0AAAA — Igniter + Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HSBA0AAAA — Igniter + Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online