OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM hot surface igniter (part 1171306) with its matching igniter wiring kit (part 1188370) is the ignition source for your ICP / Tempstar / Heil RGS091HFBB0AAAA gas furnace. On a call for heat the control board sends line voltage to the igniter, which glows white-hot and lights the gas at the burners. Igniters are brittle silicon-carbide or nitride elements that degrade with every heating cycle, and they are the most common no-heat failure on modern furnaces. Symptoms include the furnace clicking and trying to light but never igniting, a cracked or visibly broken igniter, no glow on a heat call, or short-cycling that ends in a hard lockout.
| Spec | Value |
|---|---|
| Part Number | 1171306 (Igniter), 1188370 (Wiring Kit) |
| Type | Hot Surface Igniter |
| Brand | ICP (Tempstar / Heil) |
| Includes | Igniter + Igniter Wiring Harness Kit |
| Application | Gas Furnace Ignition |
| Fits Model | RGS091HFBB0AAAA |
Built for the ICP / Tempstar / Heil RGS091HFBB0AAAA gas furnace and other ICP-family furnaces using this hot surface igniter and harness. The included wiring kit ensures a clean, OEM-spec connection to the existing furnace harness.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.