Overview

This is a genuine OEM hot surface igniter assembly for the ICP/Heil/Tempstar RGS091HDAA0AAAA gas furnace. The kit includes the igniter element (OEM #1171306) and the matching igniter wiring kit (OEM #1188370). The hot surface igniter (HSI) energizes at the start of each heat cycle, glowing to roughly 2000°F to ignite the burner gas. It is one of the most common furnace failure points because the brittle silicon-carbide element degrades with every ignition cycle. A failed igniter is the leading cause of no-heat calls. Replacing it with the correct OEM part restores reliable, on-demand ignition without nuisance lockouts.

Specifications

Spec Value
Igniter Part Number 1171306 (IGNITOR)
Wiring Kit Part Number 1188370 (WIRING KIT IGNITER)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120V
Fits Model RGS091HDAA0AAAA
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP/Heil/Tempstar RGS091HDAA0AAAA furnace and the shared RGS091 gas furnace platform. Always confirm the OEM part number on your existing igniter and wiring harness before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the furnace burner compartment service panel.
  3. Document — Photograph the igniter wiring and connector orientation before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter without touching the ceramic element.
  5. Install — Mount the new igniter in the same position, install the new wiring kit, and reconnect per your photo. Handle the silicon-carbide element by its base only.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • No heat — blower runs but burners never ignite.
  • Visible cracks, breaks, or white discoloration on the igniter element.
  • Furnace locks out after several failed ignition attempts.
  • Igniter does not glow during the call for heat.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HDAA0AAAA — Includes Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HDAA0AAAA — Includes Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HDAA0AAAA — Includes Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online