This ICP Hot Surface Igniter Kit pairs the OEM igniter (part 1171306) with the matching OEM igniter wiring kit (part 1188370) for the ICP / Tempstar / Heil RGS090STBB0AAA gas furnace. The hot surface igniter is energized at the start of each heat call and glows red-hot to ignite the burner gas; the included wiring harness ensures a clean, correct electrical connection back to the control board. Igniters are brittle and have a finite service life — the element develops hairline cracks, oxidizes, and eventually fails to reach ignition temperature, leaving the furnace in no-heat lockout. Replacing the igniter together with its wiring kit eliminates intermittent connection faults and restores fast, reliable ignition.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Voltage 120V
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS090STBB0AAA furnace and matching RGS090 platform variants. Confirm your igniter part number before ordering.

Installation Guide

  1. Safety First – Disconnect power and verify zero voltage with a multimeter.
  2. Access – Remove the burner compartment service panel.
  3. Document – Photograph the igniter position and harness routing before disconnecting.
  4. Remove – Unplug the igniter connector, remove the mounting screw, and carefully withdraw the fragile igniter; never touch the element with bare fingers.
  5. Install – Mount the new igniter, connect the new wiring kit, and route the harness clear of hot surfaces.
  6. Test – Restore power, start a heat call, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • Furnace fails to ignite and locks out after several attempts.
  • Igniter does not glow or glows weakly during a heat call.
  • Visible cracks, blistering, or white oxidation on the igniter element.
  • Intermittent no-heat caused by a brittle or damaged igniter harness.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090STBB0AAA – With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090STBB0AAA – With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090STBB0AAA – With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online