Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS090STAB0AAA — OEM 1171306 with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS090STAB0AAA — OEM 1171306 with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS090STAB0AAA furnace includes the igniter (part 1171306) and the matching igniter wiring kit (part 1188370). On each heat call, the control board energizes the igniter, which heats to a glowing temperature to ignite the burner gas. Hot surface igniters are brittle and wear out — the silicon nitride or carbide element cracks, develops hairline fractures, or simply ages until it no longer reaches ignition temperature. Bundling the wiring kit ensures the harness and connector are fresh, eliminating the corroded or heat-damaged leads that often accompany a failed igniter.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter with Wiring Harness
Brand ICP (Tempstar / Heil)
Application Gas Furnace Burner Ignition
Fitment OEM Direct Replacement

Compatibility

Engineered for the burner ignition system of the ICP / Tempstar / Heil RGS090STAB0AAA furnace. The included wiring kit matches the OEM connector so no splicing is required. Handle the igniter element by the ceramic base only — never touch the hot surface.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photo the igniter position and wiring route before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter — handle by the base only.
  5. Install — Mount the new igniter without touching the element, then connect the new wiring kit to the control board.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace ignites intermittently or fails to light
  • Igniter shows visible cracks or no longer glows
  • Repeated ignition lockouts on the control board
  • Cold air with no burner flame after the inducer runs

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090STAB0AAA — OEM 1171306 with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090STAB0AAA — OEM 1171306 with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090STAB0AAA — OEM 1171306 with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online