Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS090SRCA0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS090SRCA0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit (igniter part 1171306 with wiring harness kit 1188370) is the ignition source for the ICP RGS090SRCA0AAA gas furnace. On a call for heat the control board sends line voltage to the igniter, which glows red-hot and ignites the gas as it leaves the burners. Hot surface igniters are brittle and degrade with every heating cycle — the most common cause of no-heat calls. The included wiring kit ensures a clean, factory-correct electrical connection. Typical failure symptoms include a furnace that clicks and cycles but never lights, a glowing-then-cooling igniter that never ignites gas, or a hairline crack in the silicon-carbide element.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Element Silicon Carbide
Includes Igniter + Wiring Harness Kit

Compatibility

Direct OEM replacement for the ICP RGS090SRCA0AAA furnace and related Tempstar, Heil, and Comfortmaker models that use this hot surface igniter and harness. Verify your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Shut off gas at the furnace valve and disconnect electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter mounting and wire routing before removal.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and withdraw the old igniter without touching the new element with bare fingers.
  5. Install — Mount the new igniter, install the supplied wiring kit, and reconnect the harness per your photo.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace ignites intermittently or fails to light on cold mornings
  • Igniter shows a visible crack or no longer glows
  • Furnace locks out after several failed ignition attempts
  • Burners delay or fail to ignite after the igniter heats

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090SRCA0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090SRCA0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090SRCA0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online