Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS090SRAA0AGAA — with Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS090SRAA0AGAA — with Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306) ships with its matching igniter wiring kit (part number 1188370) for the ICP / Tempstar / Heil RGS090SRAA0AGAA gas furnace. On each heating call the control board sends voltage to the igniter, which glows white-hot to light the burners — no pilot light required. Hot surface igniters are a wear item: the silicon-carbide or silicon-nitride element grows brittle from repeated thermal cycling and eventually cracks, leaving you with no heat and a furnace that locks out after several failed ignition attempts. Because the included wiring kit refreshes the connector and leads, you avoid the intermittent no-heat faults caused by a degraded harness. Handle the new igniter only by its ceramic base — skin oils shorten element life.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fits Model RGS090SRAA0AGAA
Includes Igniter element + wiring harness kit
Fit OEM factory replacement

Compatibility

Built for the ICP RGS090SRAA0AGAA and shared ICP-platform gas furnaces (Tempstar, Heil, Comfortmaker, Day & Night) using this hot surface igniter and connector. Confirm the igniter style and mounting against your unit's parts list before ordering.

Installation Guide

  1. Safety First — Disconnect power to the furnace and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and harness routing before disconnecting.
  4. Remove — Unplug the igniter harness, unscrew the igniter bracket, and lift the fragile element clear of the burner.
  5. Install — Mount the new igniter (touch only the ceramic base), install the new wiring kit, and seat the connector fully.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and lights the burners on the first try.

Signs You Need a Replacement

  • No heat — burners never light on a call
  • Igniter no longer glows or glows weakly
  • Furnace locks out after repeated ignition attempts
  • Visible cracks or chips in the igniter element

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090SRAA0AGAA — with Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090SRAA0AGAA — with Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090SRAA0AGAA — with Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online