Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS090SFAA0AKAA - With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS090SFAA0AKAA - With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for ICP/Heil/Tempstar model RGS090SFAA0AKAA includes the igniter (part 1171306) and its matching wiring kit/harness (part 1188370). On a call for heat, the furnace control sends voltage to the igniter, which glows white-hot and lights the gas at the burners. Hot surface igniters are brittle and degrade with every heating cycle, eventually cracking or losing the ability to reach ignition temperature. Including the wiring kit ensures clean, corrosion-free connections to the new igniter. Common failure symptoms include a furnace that ignites the inducer and gas valve but never lights the burners, repeated lockouts, or an igniter that no longer glows. Replacing the igniter and harness together restores dependable ignition.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter + Wiring Harness
Brand ICP / Heil / Tempstar
Function Ignites burner gas on a call for heat

Compatibility

Direct-fit OEM replacement for ICP, Heil, Tempstar, and Comfortmaker model RGS090SFAA0AKAA and related RGS090 series furnaces that use igniter 1171306. Confirm the igniter mounting style and part number against your existing unit before ordering.

Installation Guide

  1. Safety First - Disconnect electrical power and verify zero voltage with a multimeter; shut off the gas if servicing the burner area.
  2. Access - Remove the burner-compartment service panel.
  3. Document - Photograph the igniter position and wiring routing before disconnecting.
  4. Remove - Unplug the igniter harness, remove the mounting screw(s), and lift out the old igniter without touching the element.
  5. Install - Mount the new igniter (handle only by the ceramic base), connect the new wiring kit, and route leads clear of hot surfaces.
  6. Test - Restore power and gas, then confirm the igniter glows and the burners light on a call for heat.

Signs You Need a Replacement

  • Furnace runs the inducer but burners never light
  • Igniter does not glow on a call for heat
  • Visible cracks or breaks in the igniter element
  • Repeated ignition lockouts or short-cycling on heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090SFAA0AKAA - With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090SFAA0AKAA - With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090SFAA0AKAA - With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online