Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS090LTAB0AAA — OEM 1171306 + Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS090LTAB0AAA — OEM 1171306 + Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (ICP part number 1171306), bundled with its matching igniter wiring kit (1188370), is the ignition source for the ICP/Heil/Tempstar RGS090LTAB0AAA gas furnace. On each heat call the control board energizes the igniter, which glows to roughly 2000°F and lights the burners. Hot surface igniters are brittle and degrade with every cycle; the silicon-carbide or nitride element eventually cracks or loses resistance. Typical failure signs are no ignition, the furnace locking out after several trials, or a visibly cracked/whitened element. The included wiring kit ensures clean, correct connections and proper strain relief.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Fits Model RGS090LTAB0AAA
Includes Igniter + wiring harness kit
Fit OEM exact replacement

Compatibility

Built for the ICP/Heil/Tempstar/Comfortmaker RGS090LTAB0AAA and platform-mate furnaces specifying igniter 1171306 with wiring kit 1188370. Confirm the part numbers against your furnace's ignition assembly before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, unscrew the bracket, and withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter (handle by the ceramic base only), connect using the new wiring kit, and confirm correct gap to the burner.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm glow and burner light-off.

Signs You Need a Replacement

  • Furnace blower runs but burners never light
  • Repeated ignition lockout after several trials
  • Cracked, chipped, or whitened igniter element
  • No glow visible during the ignition sequence

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090LTAB0AAA — OEM 1171306 + Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090LTAB0AAA — OEM 1171306 + Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090LTAB0AAA — OEM 1171306 + Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online