Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS090LTAA0AAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS090LTAA0AAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit pairs the genuine igniter (part number 1171306) with its matching igniter wiring kit (part number 1188370) for the ICP/Heil/Tempstar RGS090LTAA0AAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows red-hot and lights the gas at the burners. Hot surface igniters are brittle and degrade with every heating cycle — they crack, develop hairline fractures, or lose conductivity over time. The included wiring kit replaces the harness pigtail and connector so you are not reusing a brittle, heat-stressed plug. Together they restore dependable first-try ignition.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Kit Contents Igniter + wiring/connector kit
Application Gas furnace burner ignition

Compatibility

Direct OEM fit for the ICP/Heil/Tempstar RGS090LTAA0AAA and related RGS090 furnaces using this igniter and connector. Confirm mounting bracket and connector style against your old igniter before installing.

Installation Guide

  1. Safety First — Turn off gas and electrical power, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment panel.
  3. Document — Photograph the igniter position, bracket, and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the old igniter without touching the element with bare fingers.
  5. Install — Splice in the new wiring kit if needed, mount the new igniter so the element sits in the burner flame path, and connect the harness.
  6. Test — Restore gas and power, run a heat call, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • No heat with no glow at the igniter on a heat call
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after repeated failed ignition attempts
  • Burned or melted igniter connector

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090LTAA0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090LTAA0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090LTAA0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online