Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for X9MPD075F12B3 — HSI Ignition | Ships Today
ICP

ICP Hot Surface Igniter for X9MPD075F12B3 — HSI Ignition | Ships Today

SKU: X9MPD075F12B3 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter (HSI), part number 1172533, for the ICP Tempstar Heil X9MPD075F12B3 gas furnace. On a call for heat, the control board energizes the igniter, which glows red-hot to ignite the gas at the burners. The silicon-carbide/silicon-nitride element is brittle and degrades with each heating cycle, making it one of the most common furnace failure points. A cracked or worn igniter causes no-heat calls, repeated ignition lockouts, or a furnace that cycles the inducer and gas valve but never lights. This igniter works alongside the matching flame sensor (1172543) and snap-mount gas valve (1172541, VR8205S) in this model's ignition system.

Specifications

Spec Value
Part Number 1172533
Type Hot Surface Igniter (HSI)
Brand ICP (Tempstar / Heil)
Related Parts 1172543 Flame Sensor, 1172541 Gas Valve (VR8205S)
System HSI Ignition
Fit OEM Replacement

Compatibility

Engineered for the ICP Tempstar Heil X9MPD075F12B3 gas furnace. The 1172533 HSI is shared across many ICP-family (Tempstar, Heil, Comfortmaker, Arcoaire) furnace platforms using the same ignition module. Verify the igniter plug and mounting bracket match your existing part before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter bracket position and wiring harness routing.
  4. Remove — Unplug the igniter connector and remove the mounting screw. Handle the element only by its ceramic base — never touch the silicon element.
  5. Install — Mount the new igniter in the same position, reconnect the harness, and confirm proper clearance to the burner.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace will not light — no glow at the igniter on a heat call
  • Visible cracks, chips, or fractures in the igniter element
  • Repeated ignition lockouts after several failed trials
  • Inducer and gas valve cycle but burners never ignite

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP X9MPD075F12B3 — HSI Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP X9MPD075F12B3 — HSI Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP X9MPD075F12B3 — HSI Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online