This OEM hot surface igniter (HSI) is the direct ignition source for the ICP / Tempstar / Heil X8MPV075F14A3 two-stage gas furnace. On a call for heat, the control board energizes the igniter (OEM part 1172533) until it glows white-hot, lighting the main burners as the gas valve opens. A failed igniter is one of the most common no-heat causes: the silicon-nitride element grows brittle with repeated thermal cycling and eventually cracks, leaving the furnace unable to light. Typical symptoms include the furnace running its full ignition sequence with no flame, the igniter glowing weakly or not at all, repeated lockouts after several attempts, or hard cold-start clicking with no burner light. On this model the igniter works alongside the flame sensor (1172543) and a two-stage snap-mount gas valve (1172542 VR8205Q), so a healthy igniter is critical to reliable ignition and flame proving across both heat stages.
| Spec | Value |
|---|---|
| Primary Part Number | 1172533 (IGNITOR HSI) |
| Related OEM Parts | 1172543 (Flame Sensor), 1172542 (2-Stage Gas Valve VR8205Q) |
| Type | Hot Surface Igniter, silicon nitride |
| Brand | ICP / Tempstar / Heil |
| Voltage | 120 VAC |
| Fits Model | X8MPV075F14A3 |
Engineered as the factory ignition component for the ICP/Tempstar/Heil X8MPV075F14A3 75,000 BTU two-stage gas furnace. Confirm your model and igniter mounting bracket against the existing part before ordering. This OEM-grade replacement mounts and wires identically to the original.