The hot surface igniter (OEM #1172533) is the ignition element on your ICP / Tempstar / Heil X8MPT075F14A2 two-stage gas furnace. On a heat call, the control board energizes this igniter; it glows red-hot (roughly 1,800–2,500°F) and lights the gas burners as the valve opens. The HSI is the most common furnace no-heat failure — the brittle silicon-carbide/silicon-nitride element fatigues a little with every cycle until it finally cracks. Telltale symptoms are a furnace that clicks and runs the inducer but never lights, no glow through the sight port, repeated ignition lockouts with a flashing fault code, or cold air from the registers. This OEM HSI is a direct-fit replacement rated for 120V and matched to the X8MPT ignition sequence.
| Spec | Value |
|---|---|
| Primary Part Number | 1172533 (IGNITOR HSI) |
| Companion Parts | 1172543 (Flame Sensor HSI), 1172542 (2-Stage Gas Valve, HW VR8205Q) |
| Type | Hot Surface Igniter (HSI) |
| Brand | ICP / Tempstar / Heil |
| Voltage | 120 VAC |
| Application | Two-stage gas furnace ignition |
| Fitment | OEM direct replacement |
Engineered for the ICP-family X8MPT075F14A2 two-stage gas furnace and shared across the Tempstar, Heil, Comfortmaker, and Day & Night badge-engineered equivalents using the same burner assembly. Confirm the part number on your existing igniter and the model/serial tag in the blower compartment before ordering.
Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee — if it doesn't fit your X8MPT075F14A2, we make it right.