Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for X8MPN075B12A3 — HSI Kit | Ships Today
ICP

ICP Hot Surface Igniter for X8MPN075B12A3 — HSI Kit | Ships Today

SKU: 1172533 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part number 1172533) for the ICP Tempstar Heil X8MPN075B12A3 gas furnace. The hot surface igniter (HSI) glows red-hot on a thermostat call and ignites the burner gas as the gas valve opens. It works alongside the flame sensor (1172543) that proves the flame and the snap-acting gas valve (1172541, Honeywell VR8205S) that meters fuel — together these make up the furnace's ignition system. The igniter is the most frequently replaced ignition component because its element is brittle and degrades with every heating cycle. A cracked or burned-out igniter is the leading cause of a furnace that clicks, draws but never lights, and locks out on failed ignition.

Specifications

Spec Value
Part Number 1172533
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Related Flame Sensor 1172543
Related Gas Valve 1172541 (Honeywell VR8205S)
Application Furnace burner ignition

Compatibility

Designed for the ICP Tempstar Heil X8MPN075B12A3 gas furnace and other N-series furnaces using the same HSI ignition platform. Handle the igniter only by its ceramic base — skin oils shorten element life.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas supply, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter bracket position and wiring connector before disconnecting.
  4. Remove — Unplug the igniter lead, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install — Seat the new igniter at the correct depth and alignment to the burner, fasten the screw, and reconnect the lead per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burner lights and stays lit.

Signs You Need a Replacement

  • Igniter no longer glows during the ignition sequence
  • Visible cracks, blisters, or breaks in the ceramic element
  • Furnace clicks and the inducer runs but the burner never lights
  • Control board locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP X8MPN075B12A3 — HSI Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP X8MPN075B12A3 — HSI Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP X8MPN075B12A3 — HSI Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online