Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WUGF060AG01 — Silicon Carbide 120V | Ships Today
ICP

ICP Hot Surface Igniter for WUGF060AG01 — Silicon Carbide 120V | Ships Today

SKU: WUGF060AG01 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter (part number 606996, "IGNITOR X") for the ICP / Tempstar / Heil WUGF060AG01 gas furnace. The hot surface igniter glows red-hot on each call for heat to light the gas at the burners. It runs on 120V and is a high-wear consumable: its silicon carbide element weakens with every ignition cycle and ultimately cracks or fails open. A failed igniter means the furnace cannot light, leaving the home without heat. Watch for no flame on a heat call, the furnace locking out after several attempts, or the control board flashing an ignition-failure code. The element is brittle, so even minor mishandling or thermal shock can crack it and end its service life.

Specifications

Spec Value
Part Number 606996 (Ignitor X)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil / Comfortmaker
Element Silicon Carbide
Voltage 120V
Fitment OEM Direct Replacement

Compatibility

Directly fits the ICP / Tempstar / Heil WUGF060AG01 upflow gas furnace and many other ICP-family furnaces that use the 606996 igniter. Confirm your existing igniter part number and bracket/plug style before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter harness connector and remove the mounting screw(s). Handle by the ceramic base only — never touch the gray element.
  5. Install — Mount the new igniter so the element sits in the burner flame path, reattach the screw(s), and reconnect the plug per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace will not ignite or produces no flame on a call for heat.
  • Visible crack, blistering, or white powder on the igniter element.
  • Igniter no longer glows red during the ignition sequence.
  • Control board reports an ignition-failure or lockout fault code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WUGF060AG01 — Silicon Carbide 120V | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WUGF060AG01 — Silicon Carbide 120V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WUGF060AG01 — Silicon Carbide 120V | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online