Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG4604090RKB1 — Silicon Nitride HSI | Ships Today
ICP

ICP Hot Surface Igniter for WPG4604090RKB1 — Silicon Nitride HSI | Ships Today

SKU: 1186861 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter is the ignition source for the ICP/Tempstar/Heil WPG4604090RKB1 packaged gas unit. It replaces OEM part numbers 1186861 (control board igniter) and 1177663 (ignitor). The silicon nitride element heats to roughly 2,000°F when the control board energizes it, lighting the burner gas on each heat call. When an igniter cracks, develops hot spots, or loses resistance, the furnace will fail to light, lock out after several trial-for-ignition attempts, or short-cycle. A 120V hot surface igniter is one of the most common no-heat failure points on packaged gas equipment.

Specifications

Spec Value
Part Numbers 1186861, 1177663
Type Hot Surface Igniter (HSI)
Element Silicon Nitride
Brand ICP / Tempstar / Heil
Voltage 120V
Fits Model WPG4604090RKB1

Compatibility

Designed for the ICP WPG4604090RKB1 packaged gas/electric unit and shared-platform Tempstar, Heil, and Comfortmaker WPG-series furnaces using the same ignition control. Always confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photo the igniter bracket and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out without touching the ceramic element.
  5. Install — Mount the new igniter (handle the element by the ceramic base only), reseat the bracket, and reconnect the harness.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace clicks and tries to start but never lights
  • Visible cracks, blisters, or breaks in the ceramic element
  • Ignition lockout after 3 trial attempts
  • No glow when the igniter should be energized

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4604090RKB1 — Silicon Nitride HSI | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4604090RKB1 — Silicon Nitride HSI | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4604090RKB1 — Silicon Nitride HSI | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online