This OEM hot surface igniter assembly — covering ICP part numbers 1186861 (control board igniter) and 1177663 (ignitor) — is the ignition source for the gas section of the ICP / Tempstar / Heil WPG4604090LKA1 packaged gas-electric unit. On a heat call the control board energizes the igniter, which glows white-hot and lights the burners as the gas valve opens. The silicon element is the single most replaced part in a gas furnace because it is brittle, runs at extreme temperature, and degrades with every ignition cycle. A cracked or worn igniter is the most common cause of "furnace clicks but won't light" no-heat calls.

Specifications

Spec Value
Part Numbers 1186861, 1177663
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fit OEM direct replacement

Compatibility

Designed for the ICP WPG4604090LKA1 gas-electric packaged unit and shared across many Tempstar, Heil, and Comfortmaker furnaces that use this igniter platform. Handle the silicon element only by its ceramic base — skin oils cause premature failure.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/blower access panel.
  3. Document — Photograph the igniter bracket position and wiring harness routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s), then withdraw the element without touching the silicon tip.
  5. Install — Mount the new igniter so the element sits in the burner flame path, then reconnect the harness per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace clicks and tries to start but never lights (no heat)
  • Igniter no longer glows when energized
  • Visible crack, blister, or break in the silicon element
  • System short-cycles or locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4604090LKA1 — Furnace Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4604090LKA1 — Furnace Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4604090LKA1 — Furnace Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online