Overview

This OEM hot surface igniter lights the burners on the gas-heat section of your ICP package unit. On a call for heat, the igniter control board (PN 1186861) sends voltage to the igniter (PN 1177663), which glows red-hot to ignite the gas as the valve opens. Hot surface igniters are brittle and wear out with every heating cycle — the silicon-carbide or nitride element develops hairline cracks, oxidizes, and eventually fails to reach ignition temperature. The classic symptom is a furnace that goes through its pre-purge but never lights, or one that locks out after several failed ignition attempts. Replacing the igniter and its control board together restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1177663 (igniter), 1186861 (igniter control board)
Type Hot surface igniter
Brand ICP / Heil / Tempstar
Function Burner ignition on heat call
Fitment OEM, model WPG4484115RKA1

Compatibility

Factory-correct hot surface igniter and igniter control board for the ICP / Tempstar / Heil WPG4484115RKA1 gas-heat package unit. Also fits ICP-family furnaces using the same ignition platform — confirm your existing igniter's terminal/plug style before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply; verify zero voltage with a multimeter.
  2. Access — Remove the service panel and locate the igniter at the burner assembly.
  3. Document — Photograph the igniter mounting and the control board harness connections.
  4. Remove — Unplug the igniter lead and remove its mounting screw; handle the old element by the bracket only. Swap the control board if included.
  5. Install — Mount the new igniter without touching the element with bare fingers, then reconnect the harness per your photo.
  6. Test — Restore gas and power, call for heat, and watch for a clean glow, ignition, and steady flame.

Signs You Need a Replacement

  • Furnace runs the inducer and pre-purge but never lights.
  • Igniter does not glow or glows dimly.
  • Visible cracks or breaks in the igniter element.
  • Control lockout after multiple failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4484115RKA1 — With Igniter Control Board | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4484115RKA1 — With Igniter Control Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4484115RKA1 — With Igniter Control Board | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.