Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG4424060LKB1 — OEM Ignitor & Control | Ships Today
ICP

ICP Hot Surface Igniter for WPG4424060LKB1 — OEM Ignitor & Control | Ships Today

SKU: 1186861 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter assembly (ignitor PN 1177663, with control board igniter PN 1186861) replaces the failed ignition component in the ICP/Heil/Tempstar WPG4424060LKB1 packaged gas furnace section. The hot surface igniter glows bright orange when the control board sends 120V to it, lighting the burners at the start of every heat cycle. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that crack from thermal cycling, age, or oil contamination from bare fingers. A cracked or worn igniter is the single most common cause of no-heat furnace calls.

Specifications

Spec Value
Part Numbers 1177663 (Ignitor), 1186861 (Control Board Igniter)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Operating Voltage 120 VAC
Application Furnace Burner Ignition
Fits Model WPG4424060LKB1

Compatibility

Direct OEM fit for the ICP, Heil, Comfortmaker, and Tempstar WPG4424060LKB1 packaged gas/electric unit. The same hot surface igniter design serves numerous ICP-family furnaces that use 120V silicon ignition. Match the mounting bracket and plug connector to your original before installing for a true bolt-in replacement.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace section's burner compartment access panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before removal.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old igniter by the ceramic base only.
  5. Install — Mount the new igniter without touching the element, align it over the burner, and reconnect the plug per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light reliably.

Signs You Need a Replacement

  • Furnace blows cold air — burners never light.
  • Igniter shows a visible crack or no longer glows.
  • Repeated ignition lockouts and short-cycling on a call for heat.
  • Glows weakly or only on part of the element.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4424060LKB1 — OEM Ignitor & Control | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4424060LKB1 — OEM Ignitor & Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4424060LKB1 — OEM Ignitor & Control | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online