Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG4364060LKB1 — OEM 1177663 | Ships Today
ICP

ICP Hot Surface Igniter for WPG4364060LKB1 — OEM 1177663 | Ships Today

SKU: 1186861 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (ignitor part 1177663) lights the burners on the gas heat section of the ICP / Tempstar / Heil WPG4364060LKB1 packaged unit, and pairs with the matching igniter control board (part 1186861) that sequences and powers the ignition. On a call for heat the control board energizes the igniter; it glows white-hot to ignite the gas as the valve opens. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that crack from age, thermal cycling, or being touched with bare fingers — and a cracked igniter is the single most common no-heat failure on this style of furnace. Symptoms include the inducer and igniter sequence starting but no flame, or a hard lockout after several failed ignition attempts.

Specifications

Spec Value
OEM Part Number 1177663 (igniter), 1186861 (igniter control board)
Part Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Function Burner ignition for gas heat section
Handling Do not touch the element — oils cause premature failure
Fits Model WPG4364060LKB1

Compatibility

Direct-fit replacement for the ICP WPG4364060LKB1 packaged gas/electric unit and compatible across Tempstar, Heil, and Comfortmaker WPG-series furnaces using this hot surface ignition system. Confirm the igniter mounting bracket and plug match your original 1177663 before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter; shut off the gas before servicing.
  2. Access — Remove the burner / control access panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter bracket position and the plug connection before removing anything.
  4. Remove — Unplug the igniter harness and unscrew the bracket; handle the old igniter by the ceramic base only.
  5. Install — Mount the new igniter by its ceramic base — never touch the element — align it over the burner, and reconnect the harness per your photo.
  6. Test — Restore power and gas, start a heat cycle, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Igniter does not glow on a call for heat.
  • Visible crack or break in the igniter element.
  • Furnace locks out after repeated failed ignition attempts.
  • Inducer runs and gas valve clicks but no flame is established.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4364060LKB1 — OEM 1177663 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4364060LKB1 — OEM 1177663 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4364060LKB1 — OEM 1177663 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online