Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG4364060LKA1 — OEM 1186861 | Ships Today
ICP

ICP Hot Surface Igniter for WPG4364060LKA1 — OEM 1186861 | Ships Today

SKU: 1186861 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter is the direct-fit ignition component for the ICP (Tempstar/Heil) WPG4364060LKA1 packaged gas furnace. The igniter draws current and glows red-hot to ignite the gas at the burner during each heating cycle. It is one of the most frequently replaced furnace parts because the silicon carbide or silicon nitride element is brittle and degrades with every ignition cycle. Failure symptoms include the furnace failing to light, the blower running with no heat, repeated lockouts, or a cracked/blackened igniter element. This listing covers OEM control-board igniter assembly 1186861 and ignitor 1177663.

Specifications

Spec Value
Part Numbers 1186861, 1177663
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model WPG4364060LKA1
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Engineered as a factory replacement for the ICP/Tempstar/Heil WPG4364060LKA1 packaged gas system. Always confirm your existing part number and connector style against 1186861 / 1177663 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas.
  2. Access — Remove the burner/service panel.
  3. Document — Photograph the igniter wiring and mounting position before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old igniter by the ceramic base only.
  5. Install — Mount the new igniter without touching the element, reconnect the plug per your photo, and secure the screw.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace will not light or ignites intermittently.
  • Visible cracks, blistering, or black spots on the igniter element.
  • Repeated ignition lockouts or short cycling on a call for heat.
  • Blower runs but no warm air is produced.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4364060LKA1 — OEM 1186861 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4364060LKA1 — OEM 1186861 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4364060LKA1 — OEM 1186861 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online