Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG4304060RKA1 — Igniter & Control Board | Ships Today
ICP

ICP Hot Surface Igniter for WPG4304060RKA1 — Igniter & Control Board | Ships Today

SKU: 1186861 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface ignition assembly fits the ICP / Tempstar / Heil WPG4304060RKA1 gas furnace and covers the igniter (part number 1177663) and the igniter control board (part number 1186861). A hot surface igniter is a small ceramic element that glows red-hot when energized, lighting the gas at the burners during each heat call. The control board manages the ignition sequence — timing the igniter warm-up, opening the gas valve, and confirming flame. Igniters are fragile and degrade over thousands of heating cycles; the brittle element eventually cracks or burns out, and the furnace can no longer light. This is the single most common reason a gas furnace fails to produce heat. Replacing a worn igniter restores reliable, fast ignition on every cycle.

Specifications

Spec Value
OEM Part Numbers 1177663 (Igniter), 1186861 (Igniter Control Board)
Type Hot Surface Igniter
Application Gas Furnace Ignition
Brand ICP / Tempstar / Heil
Fitment OEM Direct Replacement

Compatibility

Designed as a direct-fit replacement for the ICP WPG4304060RKA1 and the Tempstar, Heil, and Comfortmaker furnaces sharing this ignition system. Verify your existing igniter and board part numbers before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and all wiring before disconnecting.
  4. Remove — Unplug the igniter lead and remove its mounting screw; handle the ceramic element only by its base — never touch the glow surface.
  5. Install — Mount the new igniter and reconnect, replacing the control board if included, per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace clicks but won't light.
  • Igniter no longer glows during a heat call.
  • Visible cracks or breaks in the ceramic element.
  • Repeated ignition lockouts or short-cycling on heat.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4304060RKA1 — Igniter & Control Board | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4304060RKA1 — Igniter & Control Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4304060RKA1 — Igniter & Control Board | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online