This genuine OEM hot surface igniter (part 1177663) — paired with its igniter control board (part 1186861) — provides ignition for the ICP/Heil/Tempstar WPG4304060LKA1 packaged gas furnace. On a heat call, the control board energizes the igniter, which glows to a high temperature and lights the burner gas. Hot surface igniters are brittle and wear out from repeated thermal cycling; the element develops hairline cracks or simply fails to reach ignition temperature. When the igniter fails, the furnace runs the inducer and opens the gas valve but never lights, then locks out. Replacing a worn igniter (and its control when faulted) restores reliable, clean ignition.

Specifications

Spec Value
Part Number 1177663 (igniter) + 1186861 (igniter control board)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar / Comfortmaker
Function Direct burner ignition
Fitment OEM exact-fit for WPG4304060LKA1

Compatibility

Direct OEM replacement for the ICP/Heil/Tempstar WPG4304060LKA1 and related WPG-series furnaces using this hot surface igniter and igniter control. Handle the igniter element by the ceramic base only — never touch the carbide tip.

Installation Guide

  1. Safety First — Disconnect power at the breaker and shut off the gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner/control access panel.
  3. Document — Photograph the igniter bracket position and the control board wiring before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old element out without touching the tip.
  5. Install — Mount the new 1177663 igniter (and 1186861 control if replacing), reconnect per your photo, holding the element by its ceramic base only.
  6. Test — Restore power and gas, call for heat, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Inducer runs and gas valve opens but burners never light
  • Igniter shows visible cracks or no longer glows
  • Furnace locks out after several failed ignition attempts
  • Out-of-range resistance reading across the igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4304060LKA1 — OEM 1177663 w/ Igniter Control 1186861 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4304060LKA1 — OEM 1177663 w/ Igniter Control 1186861 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4304060LKA1 — OEM 1177663 w/ Igniter Control 1186861 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.