Overview

This OEM hot surface igniter (OEM part numbers 1186861 and 1177663) is the ignition component for the ICP / Tempstar / Heil WPG4244060RKA1 packaged gas/electric unit. When the thermostat calls for heat, the integrated control board energizes the igniter, which glows red-hot to light the gas at the burners. A failed igniter is the single most common cause of "no heat" on these units. Igniters are consumable wear parts — repeated heating and cooling cycles eventually crack the silicon-nitride or silicon-carbide element, breaking the circuit. Symptoms include the inducer running but no flame, a furnace that clicks and tries but never lights, or a unit that locks out after three failed ignition attempts.

Specifications

Spec Value
Part Number 1186861 (Control Board Igniter), 1177663 (Igniter)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Application Gas furnace / package unit ignition
Fitment OEM direct replacement

Compatibility

Engineered as a direct OEM fit for the ICP WPG4244060RKA1 packaged gas unit and shared-platform Tempstar, Heil, and Comfortmaker WPG-series models that use OEM igniter 1186861 / 1177663. Always confirm your existing part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the unit's control/burner access panel.
  3. Document — Photograph the igniter bracket position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old igniter out. Handle only by the ceramic base — never touch the fragile element.
  5. Install — Mount the new igniter in the exact bracket position, reconnect the plug, and confirm the element sits in the burner flame path.
  6. Test — Restore gas and power, initiate a heat call, and verify the igniter glows and lights all burners cleanly.

Signs You Need a Replacement

  • Inducer runs but burners never ignite (no glow).
  • Furnace locks out after multiple ignition attempts.
  • Visible cracks, hot spots, or white/gray flaking on the element.
  • Intermittent heat that returns after a reset but fails again.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4244060RKA1 — Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4244060RKA1 — Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4244060RKA1 — Furnace Ignition Control | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.