Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG4244060LKA1 - Furnace Ignition | Ships Today
ICP

ICP Hot Surface Igniter for WPG4244060LKA1 - Furnace Ignition | Ships Today

SKU: 1186861 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter assembly (part #1177663, with related igniter control board #1186861) is the factory ignition component for the ICP/Tempstar/Heil WPG4244060LKA1 gas furnace. On each call for heat, the control board sends voltage to the igniter, which glows white-hot and lights the gas as it enters the burners. Because the igniter element repeatedly heats and cools, it is one of the most failure-prone parts in a furnace - the brittle silicon-carbide or silicon-nitride element eventually cracks, leaving the burners unable to light. A failed igniter is the single most common reason a furnace produces a no-heat call while the blower and controls otherwise appear healthy.

Specifications

Spec Value
Part Numbers 1177663 (Igniter), 1186861 (Igniter Control Board)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fitment OEM

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil WPG4244060LKA1 gas furnace. Handle the igniter element only by its ceramic base - skin oils can shorten its life.

Installation Guide

  1. Safety First - Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access - Remove the burner compartment service panel.
  3. Document - Photograph the igniter bracket position and wire routing.
  4. Remove - Unplug the igniter connector and remove the mounting screw; lift out the old igniter without touching the element.
  5. Install - Set the new igniter, secure the bracket, and reconnect the plug per your photo.
  6. Test - Restore gas and power, then watch a full ignition cycle to confirm a clean light-off.

Signs You Need a Replacement

  • Furnace blower runs but burners never light (no heat)
  • Visible cracks or breaks in the igniter element
  • Igniter no longer glows during the ignition sequence
  • Repeated ignition lockouts on the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4244060LKA1 - Furnace Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4244060LKA1 - Furnace Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4244060LKA1 - Furnace Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online