Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG4244040LKB1 — OEM Furnace Ignitor | Ships Today
ICP

ICP Hot Surface Igniter for WPG4244040LKB1 — OEM Furnace Ignitor | Ships Today

SKU: 1186861 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter is the direct-fit ignition component for the ICP / Heil / Tempstar / Comfortmaker WPG4244040LKB1 gas furnace. When a 24V call for heat begins, the control board energizes this igniter, which heats to roughly 1,800–2,500°F to light the burner gas. Igniters are the single most common no-heat failure on this furnace family — the brittle silicon-carbide or silicon-nitride element cracks from repeated thermal cycling, contamination, or rough handling. Covered OEM part numbers: 1186861 (control board igniter) and 1177663 (ignitor). Replacing a failed igniter restores reliable ignition without replacing the entire burner assembly.

Specifications

Spec Value
Part Numbers 1186861, 1177663
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar / Comfortmaker
Voltage 120V
Application Gas Furnace Ignition
Fit OEM Direct Replacement

Compatibility

Engineered for the WPG4244040LKB1 and shared across many ICP-built furnaces sold under the Heil, Tempstar, Comfortmaker, and Arcoaire badges. Always confirm your OEM part number against the failed unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and withdraw the old element without touching the ceramic body.
  5. Install — Mount the new igniter, handling it only by the porcelain base; reconnect the harness per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and lights the burners cleanly.

Signs You Need a Replacement

  • Furnace blower runs but no heat — burners never light
  • Igniter does not glow during the ignition sequence
  • Visible cracks, chips, or white-spotting on the element
  • Control board lockout after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4244040LKB1 — OEM Furnace Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4244040LKB1 — OEM Furnace Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4244040LKB1 — OEM Furnace Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online