This OEM hot surface igniter assembly (part number 1175974) is the factory ignition component for the ICP / Heil / Tempstar WPG3602115LKB1 packaged gas-electric unit. The hot surface igniter (HSI) glows red-hot when energized by the control board, lighting the burners on a call for heat. It is one of the most common wear items in a gas furnace section. A failed igniter is the leading cause of a no-heat condition: the unit will cycle, the inducer will run, but the burners never light and the system locks out. Igniters are fragile silicon-carbide or silicon-nitride elements that crack from thermal cycling, vibration, or being touched during service. This assembly ships complete with the mounting bracket and wire harness for a direct, plug-in replacement.

Specifications

Spec Value
OEM Part Number 1175974
Description Igniter Assembly (IGNITER ASY)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar / Comfortmaker
Fits Model WPG3602115LKB1
Includes Igniter element, bracket, wire harness
Fitment OEM direct replacement

Compatibility

Engineered for the ICP / Heil / Tempstar / Comfortmaker WPG3602115LKB1 packaged gas-electric system. The same igniter assembly is used across many International Comfort Products WPG-series and related packaged units. Confirm OEM part number 1175974 matches your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the burner/control access panel from the unit.
  3. Document — Photograph the igniter wiring and bracket orientation before disconnecting.
  4. Remove — Unplug the igniter harness from the control, remove the mounting screw(s), and withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter assembly by the bracket only, never the ceramic element, and reconnect the harness per your photo.
  6. Test — Restore gas and power, initiate a heat call, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • No heat — inducer runs but burners never ignite.
  • Visible crack, chip, or break in the igniter element.
  • Igniter does not glow on a heat call.
  • Furnace locks out after several failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG3602115LKB1 — OEM 1175974 Igniter Assembly | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG3602115LKB1 — OEM 1175974 Igniter Assembly | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG3602115LKB1 — OEM 1175974 Igniter Assembly | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online