The ICP hot surface igniter (OEM #1177663) is the ignition source for the WPG3424060RKC1 package gas/electric unit. On a call for heat, the integrated control energizes this igniter; it heats to roughly 1,800–2,500°F and ignites the gas at the burners. Made from durable silicon nitride, it resists the thermal cracking and shock failures common to older silicon-carbide elements. When an igniter fails you typically see no ignition, the igniter glowing but no flame, repeated lockout, or a furnace that clicks and cycles without producing heat. This is a genuine OEM-grade replacement matched to the WPG3424060RKC1.

Specifications

Spec Value
Part Number 1177663
Type Hot Surface Igniter (Silicon Nitride)
Brand ICP / Tempstar / Heil
Voltage 120V
Fitment WPG3424060RKC1
Function Burner ignition

Compatibility

Designed for the ICP / Tempstar / Heil WPG3424060RKC1 package gas/electric unit. The WPG3424060 platform shares this igniter across related package units; verify your part number against the failed component before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket and the two-wire connector before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and lift the old igniter out. Handle the ceramic element only by its base — never touch the hot surface.
  5. Install — Seat the new igniter in the bracket, secure the screw, and reconnect the harness. Confirm proper spacing over the burner per spec.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and ignites the burners cleanly.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out after several attempts
  • Igniter glows but the burners never light
  • Visible cracks, chips, or white spots on the igniter element
  • No glow at all when a heat call is initiated

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG3424060RKC1 — Silicon Nitride OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG3424060RKC1 — Silicon Nitride OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG3424060RKC1 — Silicon Nitride OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.