Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG3364060RKC1 — OEM 1177663 | Ships Today
ICP

ICP Hot Surface Igniter for WPG3364060RKC1 — OEM 1177663 | Ships Today

SKU: 1177663 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (ICP part #1177663) is the ignition source for your ICP/Tempstar/Heil WPG3364060RKC1 gas furnace. When a heat call is received, the furnace control energizes the igniter; it glows white-hot and ignites the gas at the burners. A cracked element, no glow, or repeated ignition lockouts almost always trace back to a failed igniter. Hot surface igniters are brittle and wear out over normal cycling, making this one of the most common furnace replacement parts. Installing the exact OEM igniter guarantees correct resistance, glow temperature, and bracket fit.

Specifications

Spec Value
Part Number 1177663
Part Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model WPG3364060RKC1
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WPG3364060RKC1 furnace and shared platform units using ignition assembly 1177663. Always confirm your model and part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter wiring and mounting orientation before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s). Handle by the ceramic base only — never touch the element.
  5. Install — Mount the new igniter so the element sits in the burner flame path, reconnect the harness, and reinstall the screw.
  6. Test — Restore gas and power, initiate a heat call, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Igniter does not glow on a heat call.
  • Visible crack or break in the ceramic element.
  • Furnace locks out after several failed ignition attempts.
  • No heat despite the blower and control board cycling.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG3364060RKC1 — OEM 1177663 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG3364060RKC1 — OEM 1177663 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG3364060RKC1 — OEM 1177663 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online