Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG3362060RKB1 — OEM 1175974 Igniter Assembly | Ships Today
ICP

ICP Hot Surface Igniter for WPG3362060RKB1 — OEM 1175974 Igniter Assembly | Ships Today

SKU: 1175974 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter assembly (part number 1175974) is the factory ignition component for the ICP/Tempstar/Heil WPG3362060RKB1 gas furnace. At the start of each heating cycle the furnace control board sends low voltage to the igniter, which heats to roughly 2,000°F and lights the gas as it exits the burner manifold. Because the silicon-carbide or silicon-nitride element grows brittle with every ignition, the hot surface igniter is one of the most commonly replaced furnace wear parts. Watch for symptoms like no ignition, a furnace that clicks but never lights, repeated lockouts after three or four failed attempts, or an element that no longer glows or is visibly cracked or chipped. Installing a fresh OEM igniter assembly restores dependable startup and eliminates frustrating no-heat calls.

Specifications

Spec Value
OEM Part Number 1175974
Part Type Hot Surface Igniter Assembly
Brand ICP / Tempstar / Heil
Fits Model WPG3362060RKB1
Application Gas Furnace Ignition
Fitment Genuine OEM

Compatibility

Engineered as a direct-fit replacement for the ICP/Tempstar/Heil WPG3362060RKB1 furnace. As an OEM assembly it includes the correct mounting bracket and wire harness, so it installs in the factory location without modification. Confirm your OEM part number matches 1175974 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas supply, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter, handling it only by the ceramic base, and reconnect the harness per your photo.
  6. Test — Restore gas and power, run a full heat cycle, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace will not ignite or locks out after several attempts
  • Igniter no longer glows orange-white when commanded
  • Visible cracks, chips, or hot spots on the element
  • Intermittent no-heat that comes and goes with temperature

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG3362060RKB1 — OEM 1175974 Igniter Assembly | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG3362060RKB1 — OEM 1175974 Igniter Assembly | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG3362060RKB1 — OEM 1175974 Igniter Assembly | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online