This is a genuine OEM hot surface igniter (part #1177663) for the ICP/Heil/Tempstar WPG3304040LKC1 packaged gas unit. The igniter is the heart of the furnace's ignition sequence — when the thermostat calls for heat, the control board sends 120V to the igniter, heating its silicon nitride element until it glows and lights the gas at the burners. A failed igniter is the single most common cause of a furnace that blows cold air or short-cycles in lockout. Over thousands of heating cycles the brittle element develops hairline cracks, carbon buildup, or simply burns out, breaking the ignition chain. Replacing it with the correct factory part restores reliable, on-demand heat.

Specifications

Spec Value
Part Number 1177663
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Element Silicon Nitride
Voltage 120V
Fit OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP family unit WPG3304040LKC1 and shared chassis built under the Heil, Tempstar, Comfortmaker, and Keeprite brands. Always confirm the original part number 1177663 against your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower/burner access panel.
  3. Document — Photograph the igniter bracket and the 2-pin wiring connector before disconnecting.
  4. Remove — Unplug the connector, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter, handling it only by the ceramic base, and reconnect the plug per your photo.
  6. Test — Restore power and run a full heat cycle; confirm the igniter glows and the burners light within seconds.

Signs You Need a Replacement

  • Furnace ignites no flame and locks out after several tries
  • Igniter no longer glows orange during the heat call
  • Visible cracks, blistering, or white/grey spots on the element
  • Intermittent no-heat calls that clear after a power reset

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG3304040LKC1 — OEM 1177663 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG3304040LKC1 — OEM 1177663 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG3304040LKC1 — OEM 1177663 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online