Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG3302060LKB1 — OEM 1175974 Igniter Assembly | Ships Today
ICP

ICP Hot Surface Igniter for WPG3302060LKB1 — OEM 1175974 Igniter Assembly | Ships Today

SKU: 1175974 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter assembly (part number 1175974) for the ICP/Tempstar/Heil WPG3302060LKB1 packaged gas furnace. The hot surface igniter glows red-hot on each call for heat to ignite the gas as it enters the burners. Repeated heating cycles slowly degrade the silicon-carbide or silicon-nitride element until it cracks and fails open. When that happens the furnace runs its inducer and gas-valve sequence but never lights, leaving you with cold air or a unit that locks out after several failed ignition attempts. Swapping a worn igniter is one of the most common no-heat repairs on this equipment and restores prompt, reliable ignition.

Specifications

Spec Value
Part Number 1175974
Type Hot Surface Igniter Assembly
Brand ICP (Tempstar / Heil)
Fits Model WPG3302060LKB1
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Designed as the factory-correct igniter assembly for the ICP/Tempstar/Heil WPG3302060LKB1 packaged gas unit. Always confirm your existing part number and bracket orientation before installing.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and shut off the gas supply. Verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the furnace service / blower-compartment panel to reach the burner assembly.
  3. Document — Photograph the igniter bracket position and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness connector and remove the mounting screw(s). Handle the old igniter only by its ceramic base — never touch the element.
  5. Install — Mount the new 1175974 igniter in the same position, handling only the ceramic base, and reconnect the harness per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs the inducer but never lights the burners.
  • Unit locks out after 3 failed ignition attempts (no glow visible).
  • Visible cracks, blistering, or white deposits on the igniter element.
  • Intermittent ignition — sometimes lights, sometimes drops to cold air.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG3302060LKB1 — OEM 1175974 Igniter Assembly | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG3302060LKB1 — OEM 1175974 Igniter Assembly | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG3302060LKB1 — OEM 1175974 Igniter Assembly | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online