Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WPG3244060LKC1 — OEM 1177663 | Ships Today
ICP

ICP Hot Surface Igniter for WPG3244060LKC1 — OEM 1177663 | Ships Today

SKU: 1177663 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1177663) is the ignition component for the ICP Tempstar/Heil WPG3244060LKC1 packaged gas furnace. When the thermostat calls for heat and the gas valve opens, the control board sends voltage to the igniter, which glows red-hot to ignite the burner gas. A failed igniter is one of the most common causes of no-heat calls. Over thousands of heating cycles the igniter element develops micro-cracks, carbon buildup, or simply burns out, leaving the unit unable to light. Symptoms include the furnace clicking but never firing, short-cycling on ignition lockout, or no glow visible through the inspection port during a heat call.

Specifications

Spec Value
Part Number 1177663
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Function Burner Ignition
Fitment OEM Direct Replacement

Compatibility

Designed as a direct OEM replacement for the ICP Tempstar Heil WPG3244060LKC1 packaged gas heating system. Always confirm the original igniter part number and mounting bracket before ordering, as ICP families share several igniter styles across model years.

Installation Guide

  1. Safety First — Disconnect power at the unit and shut off the gas supply. Verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the furnace/burner service panel to reach the burner assembly.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s). Handle the old igniter by the bracket only — never touch the fragile element.
  5. Install — Mount the new igniter, taking care not to touch the silicon nitride element with bare hands. Reconnect the wiring per your photo.
  6. Test — Restore gas and power, then run a full heat cycle and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace clicks and the gas valve opens but burners never ignite.
  • Unit locks out on ignition failure after several attempts.
  • No visible glow at the igniter during a heat call.
  • Cracked, chipped, or visibly burned igniter element.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG3244060LKC1 — OEM 1177663 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG3244060LKC1 — OEM 1177663 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG3244060LKC1 — OEM 1177663 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online