Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WFSR100C060A2 — With Mounting Bracket | Ships Today
ICP

ICP Hot Surface Igniter for WFSR100C060A2 — With Mounting Bracket | Ships Today

SKU: 1184324 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter kit for the ICP/Tempstar/Heil WFSR100C060A2 gas furnace. It includes the igniter (part 1176919) and its mounting bracket (part 1184324). The hot surface igniter glows to ignite the gas at each heat cycle; because it is repeatedly heated and cooled, it is one of the most common wear items in a modern furnace. A cracked or aged igniter causes ignition failure and no-heat lockouts.

Specifications

Spec Value
Part Number 1176919 (igniter), 1184324 (bracket)
Type Hot surface igniter
Brand ICP / Tempstar / Heil
Includes Igniter and mounting bracket
Element Silicon carbide / nitride hot surface

Compatibility

Direct OEM replacement for the WFSR100C060A2 furnace and related ICP-family models using this igniter and bracket assembly. Match part numbers 1176919 and 1184324 and confirm the connector style before installing. Handle the igniter element by the ceramic base only — skin oils shorten its life.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel to expose the igniter at the burner assembly.
  3. Document — Photograph the igniter position, bracket orientation, and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the bracket screw, and carefully withdraw the fragile igniter element.
  5. Install — Mount the new igniter on the included bracket, position it at the correct gap to the burner, and reconnect the lead per your photo. Touch only the ceramic base.
  6. Test — Restore power and watch a full ignition cycle; confirm the element glows bright orange and lights the burners.

Signs You Need a Replacement

  • Furnace clicks but the igniter never glows
  • Visible crack, chip, or break in the igniter element
  • Repeated ignition lockouts after several attempts
  • Weak or uneven glow that fails to light the gas

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFSR100C060A2 — With Mounting Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFSR100C060A2 — With Mounting Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFSR100C060A2 — With Mounting Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.