Overview

This OEM hot surface igniter (HSI) is the ignition source for the ICP/Tempstar/Heil WFMR090B042B1 gas furnace. On a heat call, the control board energizes the igniter, which glows to roughly 2,000°F and lights the gas burners. The kit includes the silicon-nitride igniter element (OEM 1176919) and its mounting bracket (OEM 1183455). A cracked or open igniter is a leading cause of no-heat failures: the furnace purges, fails to light, retries, and finally locks out. Installing a fresh igniter restores dependable single-attempt ignition and ends nuisance lockouts.

Specifications

Spec Value
OEM Part Number 1176919 (Igniter)
Included Bracket 1183455 (Igniter Bracket)
Type Hot Surface Igniter (HSI)
Element Silicon Nitride
Brand ICP / Tempstar / Heil
Fits Model WFMR090B042B1
Application Gas Furnace Ignition

Compatibility

Designed for the ICP-family WFMR090B042B1 gas furnace and interchangeable across the ICP, Tempstar, Heil, and Comfortmaker models that share this ignition platform. Confirm the part number against your unit's rating plate before installing.

Installation Guide

  1. Safety First — Shut off the gas and disconnect electrical power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter connector, remove the bracket screw(s), and withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter and bracket, handling the element by the ceramic base only, and reconnect the plug per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and lights the burners on the first attempt.

Signs You Need a Replacement

  • Furnace fails to light and locks out after several tries
  • Igniter is visibly cracked, blistered, or no longer glows
  • Intermittent no-heat calls, especially in cold weather
  • Resistance reads open or out of spec on a multimeter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFMR090B042B1 — Silicon Nitride HSI Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFMR090B042B1 — Silicon Nitride HSI Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFMR090B042B1 — Silicon Nitride HSI Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.