Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WFMR045A036B2 — Furnace Ignition Kit (1176919) | Ships Today
ICP

ICP Hot Surface Igniter for WFMR045A036B2 — Furnace Ignition Kit (1176919) | Ships Today

SKU: 1183455 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter assembly for the ICP/Tempstar/Heil WFMR045A036B2 gas furnace. The hot surface igniter (HSI) is the component that glows red-hot to light the burners on each heating call. When voltage is applied, the silicon-carbide or silicon-nitride element reaches over 2,000°F in seconds, igniting the gas as the valve opens. This kit covers the full ignition hardware referenced for this model: OEM 1176919 (IGNITER), 1183455 (BRACKET IGNITER), and 1176929 (VALVE N HSI SNAP WR, ref 36J24618). A cracked, eroded, or carbon-fouled igniter is the single most common cause of no-heat furnace failures. The element is fragile and degrades with every ignition cycle, so periodic replacement is normal wear.

Specifications

Spec Value
OEM Part Number 1176919 (igniter)
Bracket Part Number 1183455
Valve/HSI Hardware 1176929 (36J24618)
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil / Comfortmaker
Voltage 120 VAC
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP family WFMR045A036B2 furnace and shared platforms sold under the Tempstar, Heil, and Comfortmaker brands. Always confirm the OEM part number stamped on your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut the gas valve, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter harness connector, remove the bracket mounting screw, and lift the old igniter out without touching the fragile element.
  5. Install — Mount the new igniter and bracket, handling it only by the ceramic base, and reconnect the harness per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace blows cold air or fails to ignite on a heat call.
  • Igniter does not glow or only glows dimly.
  • Visible cracks, blisters, or white carbon buildup on the element.
  • Furnace locks out after several failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFMR045A036B2 — Furnace Ignition Kit (1176919) | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFMR045A036B2 — Furnace Ignition Kit (1176919) | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFMR045A036B2 — Furnace Ignition Kit (1176919) | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online