ICP Hot Surface Igniter for WFMR045A024B1 — Silicon Carbide Element | Ships Today
ICP

ICP Hot Surface Igniter for WFMR045A024B1 — Silicon Carbide Element | Ships Today

SKU: 1183455 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter assembly is the ignition source for the ICP Tempstar/Heil WFMR045A024B1 gas furnace. The silicon carbide element (OEM part 1176919) glows to roughly 2,500°F to ignite the burner gas on each heat call, and the kit includes the dedicated igniter mounting bracket (OEM part 1183455) plus the snap-action HSI valve component (OEM part 1176929, ref 36J24618). When an igniter fails, the furnace blower may run but produce no heat, the unit will short-cycle on failed ignition lockout, or you may hear repeated clicking from the control board attempting ignition retries. Silicon carbide igniters are fragile and degrade with every heating cycle, so they are one of the most common no-heat failure points on this furnace platform.

Specifications

Spec Value
Part Number 1176919 (Igniter), 1183455 (Bracket), 1176929 (HSI Valve)
Type Hot Surface Igniter
Element Silicon Carbide
Brand ICP (Tempstar / Heil / Comfortmaker)
Application Gas Furnace Ignition
Fitment OEM — Model WFMR045A024B1

Compatibility

Engineered as a direct OEM replacement for the ICP Tempstar/Heil WFMR045A024B1 furnace. The same igniter family is shared across many ICP-built 45,000 BTU induced-draft gas furnaces sold under the Tempstar, Heil, Comfortmaker, and Arcoaire labels. Always confirm your existing part number against 1176919 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/blower access panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter connector, remove the bracket mounting screw, and lift out the old igniter. Handle the new element by the ceramic base only — never touch the carbide.
  5. Install — Mount the new igniter and bracket, align it over the burner per your photo, and reconnect the plug.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light within the trial-for-ignition period.

Signs You Need a Replacement

  • Furnace ignites intermittently or locks out on no-flame after 3 tries
  • No glow visible from the igniter during a heat call
  • Visible cracks, blistering, or white powder on the carbide element
  • Blower runs continuously but the furnace produces only cold air

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFMR045A024B1 — Silicon Carbide Element | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFMR045A024B1 — Silicon Carbide Element | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFMR045A024B1 — Silicon Carbide Element | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online