Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WFML090B042B2 — HSI Kit | Ships Today
ICP

ICP Hot Surface Igniter for WFML090B042B2 — HSI Kit | Ships Today

SKU: 1183455 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter assembly for the ICP Tempstar Heil WFML090B042B2 gas furnace. The kit covers the igniter (part #1176919), its mounting bracket (#1183455), and the snap-in HSI valve assembly (#1176929, ref 36J24618). On each call for heat, the control board energizes the igniter, which glows red-hot and ignites the gas as it leaves the burners. Hot surface igniters are brittle and consumable — they degrade with every heating cycle and are one of the most common no-heat failure points on a modern furnace. A cracked or burned-out igniter will not glow, leaving the furnace to lock out after several failed ignition attempts.

Specifications

Spec Value
Igniter Part Number 1176919
Bracket Part Number 1183455
Snap-In HSI Valve 1176929 (36J24618)
Type Hot Surface Igniter (HSI)
Brand ICP (Tempstar / Heil)
Fit OEM Direct Replacement

Compatibility

Engineered as a direct OEM replacement igniter assembly for the ICP Tempstar Heil WFML090B042B2 gas furnace. These igniter and bracket part numbers are shared across many ICP-family furnaces marketed as Tempstar, Heil, Comfortmaker, and Arcoaire. Verify your existing igniter style and bracket footprint against the parts shown before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel to expose the igniter at the burner assembly.
  3. Document — Photograph the igniter wiring, connector routing, and bracket orientation before disconnecting.
  4. Remove — Unplug the igniter connector and unscrew the igniter/bracket. Handle by the ceramic base only — never touch the silicon-carbide element.
  5. Install — Mount the new igniter and bracket, route the harness clear of the burner flame, and reconnect per your photo.
  6. Test — Restore gas and power, initiate a call for heat, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace attempts ignition with no flame, then locks out after multiple tries.
  • Igniter does not glow during the ignition sequence.
  • Visible cracks, blisters, or white spots on the igniter element.
  • Intermittent ignition or delayed, rough light-off with a gas smell.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFML090B042B2 — HSI Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFML090B042B2 — HSI Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFML090B042B2 — HSI Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.